VARIABLE FREQUENCY INPUT 350 TO 1200 HZ 3 PHASE TO 12 PHASE MIL-PRF-27F POWER TRANSFORMERS
- Power Factor Correction: 99%
- Efficency: Greater Than 95%
- Harmonic Distortion: Less than 3% THD
- Shielded Enclosure: Eliminates EMI Emissions
(Can be safely place near sensitive receiver circuitry)
- Rad-Hard Construction
- MIL-PRF-27F Designation: TF4V03YY
|
 click wiring diagram to enlarge |
Designed to meet the need for power factor correction and harmonic distortion in airborne, shipboard, military, and telecommunications electronics.
Currently used on the Boeing 787, Airbus A380, and A400M to meet the stringent harmonic distortion requirements of ADB100.1.8, CE102, DO160F, and
MIL-STD-704 A/F
Background:
Electrical power generation and distribution systems on board commercial and military aircraft are being required to meet new standards for harmonic distortion and power factor correction. For size and weight savings, 3 phase power supply configurations are often required at power levels of 500 watts and above. Typically these systems generate harmonic currents that are reflected back into the power distribution source distorting the AC line and causing conductive interference in attached equipment.
The low power factor associated with these systems causes inefficiency, excess heating, and an increase in the size of many power components required to support the differential between real and apparent power. The methods currently employed to address these problems are typically expensive, inefficient, and require active circuitry having a significantly higher parts count with reduced reliability in comparison to a passive component solution.
Overview:
Payne Magnetics Inc. has developed a 12-phase tranformer that can be configured in a simple passive rectifier curcuit to produce a variable frequency (350 to 1200 hz) power supply capable of less than 3% total harmonic distortion, a power factor greater than 99%, and efficiency of up to 95%. The transformer is available in three sizes (70, 650, and 1000 VA) and four standard voltage outputs (28, 52 ,200, and 270 Vrms).
Custom values available.
|
SPECIFICATIONS:
Input Primary:
DELTA: 200 Vrms Line to Line
Input Variable Frequency:
350 to 1200 Hz 3 Phase
|
Output Configuration:
Four WYE Outputs
(30 Degree phase seperation each leg)
Output Voltage:
Standard Options: 28Vrms, 52Vrms, 200Vrms, and 270Vrms
Note: Custom values available on request
|
Output Power:
70, 650, and 1000 VA standard (Depending on mounting conditions) Note: Custom sizes available on request
DWV:
1500 Vrms
|
|
| Click on a part number to download a multi-phase transformer pdf specifications sheet
|
|
 |
 |
 |
|
 |